The practical answer
Peptide-related impurities are near copies of the target: deletion sequences (one residue missing), insertion sequences (one extra), capped truncated sequences, stereoisomers, and degradation products such as oxidised methionine (+15.995 Da), deamidated asparagine or glutamine (+0.984 Da), pyroglutamate (-17.027 Da from Gln) and cyclic imides (-18.011 Da). For medicines, the Ph. Eur. thresholds cited by the EMA say peptide-related impurities are reported above 0.1%, identified above 0.5% and qualified above 1.0%. [1] [2] [3] [4] [5]
Evidence, method & source dates ↓Two families: made during synthesis, or formed afterwards
The EMA guideline on synthetic peptides sorts related substances by where they come from: impurities carried in from the protected amino acid starting materials, impurities formed during synthesis and cleavage, and degradation products formed during manufacture or storage, whose levels may rise over time. [1] The distinction matters for a buyer. Process impurities are fixed when the lot is made; degradation products can grow between the certificate date and the day you use the material.
Non-peptide impurities, such as process reagents, residual solvents, elemental impurities and nitrosamines, are a separate category with their own tests. [1] This guide covers the peptide-related ones: molecules that look like the target to an HPLC detector and often differ from it by a single atom or residue.
Process-related impurities
Deletion sequences are missing one or more residues because a coupling or deprotection step did not go to completion. Manufacturers limit them by repeating couplings and acetylating unreacted chain ends; that capping produces acetylated truncated sequences instead. [1] A deletion shows up in mass spectrometry as the target mass minus one residue mass: -57.021 Da for glycine, -113.084 Da for leucine or isoleucine, -128.095 Da for lysine. [6]
Insertion sequences carry one extra copy of a residue. The EMA lists three causes: free amino acid present in the protected building block, premature deprotection during a long coupling, and excess building block not washed away before the next deprotection. [1] The mass is the target plus one residue mass.
Starting-material impurities can carry the wrong amino acid into the chain. The EMA names incorrect enantiomers or diastereomers, beta-alanine residues, dipeptides and swaps such as isoleucine in place of leucine. [1] Leucine and isoleucine have identical residue masses (113.08406 Da), so a swap is invisible to an intact-mass check. [6] Stereoisomers formed by epimerisation during coupling also have exactly the target mass. [1]
During cleavage, reactive cations released from protecting groups can attach to tryptophan, tyrosine or methionine side chains, and protecting groups that were not fully removed leave heavier variants. [1]
Degradation-related impurities
The EMA lists the pathways that can create degradation products: oxidation, hydrolysis, isomerisation, deamidation, cyclic imide (aspartimide) formation, diketopiperazine and pyroglutamic acid formation, beta-elimination, condensation, disulfide cleavage or exchange, and acetylation. It specifically mentions oxidation of cysteine and methionine. [1] Bachem notes that peptides containing Cys, Met or Trp are prone to oxidation and that Asn, Gln, Met, Cys and Trp shorten shelf life. [7]
High molecular weight impurities, such as dimers, oligomers and aggregates, form by covalent or non-covalent linkage. The EMA says a specification line that only says "high molecular weight impurities" is not acceptable for medicines; the species should be named, and size-exclusion chromatography is one technique for them. [1]
Mass shift lookup table
Use this table when a certificate or a mass spectrum notes a peak near the expected mass. Shifts are monoisotopic and per event; two oxidations add about 32 Da. [2] [3] [4] [5] [6] A shift alone is a hypothesis, not an identification: several causes share a mass, and the table flags the common collisions.
| Impurity | Typical cause | Mass shift vs target (Da, monoisotopic) | Collision to watch for |
|---|---|---|---|
| Deletion | Incomplete coupling or deprotection | Minus one residue mass (e.g. -57.021 Gly, -113.084 Leu/Ile) | Hydrolysis fragments if near a cleavage-prone bond |
| Insertion | Double coupling | Plus one residue mass | None common at the same mass |
| Acetylated truncation | Capping of unreacted chain | Shorter chain plus 42.011 | Acetylation as a degradation pathway |
| Stereoisomer (epimer) | Starting material or coupling epimerisation | 0 | Invisible to intact MS |
| Leu/Ile swap | Wrong building block | 0 | Invisible to intact MS |
| Oxidation | Met, Cys, Trp exposure | +15.995 per oxygen | Hydroxylation (same composition) |
| Deamidation | Asn or Gln to Asp or Glu | +0.984 | C-terminal acid instead of amide (+0.984) |
| Pyroglutamate | N-terminal Gln cyclises | -17.027 (from Gln); -18.011 (from Glu) | Loss of ammonia or water fragments |
| Cyclic imide (aspartimide) | Asp side chain cyclises | -18.011 | Pyroglutamate from Glu |
| Reduced disulfide | Disulfide cleavage | +2.016 (two hydrogens) | Isotope peaks at M+2 |
| Dimer | Covalent or non-covalent pairing | About twice the mass | A 2+ ion of a dimer sits at the 1+ position of the monomer |
Where the 0.1%, 0.5% and 1.0% figures come from
Synthetic peptides are outside ICH Q3A, the general impurity guideline for new drug substances. The EMA guideline instead cites the European Pharmacopoeia general monograph Substances for Pharmaceutical Use: peptide-related impurities should be reported above 0.1%, identified above 0.5% and qualified above 1.0%. Methods should be able to meet the 0.1% reporting threshold, and when impurities co-elute as one peak the 1.0% qualification threshold applies to the combined peak unless justified otherwise. [1]
Those are medicine rules, and a research-grade certificate is not required to meet them. They are still a useful yardstick. A certificate that lists a single main-peak figure and nothing else tells you nothing about any individual impurity. A certificate that lists every peak above 0.1% and names those above 0.5% gives you something you can compare between lots. If your experiment is sensitive to a specific variant, such as an oxidised form, ask for that variant to be reported by name.
A fictional certificate, decoded
Invented example: a 12-residue peptide containing one methionine, one asparagine and one glycine, with a stated monoisotopic mass of 1400.00 Da. The certificate reports HPLC purity 97.8% and lists three minor peaks with mass notes: 0.9% at +16.0 Da, 0.6% at +1.0 Da, 0.4% at -57.0 Da.
Read with the table: +16.0 Da fits methionine oxidation, a degradation product that can grow in storage. +1.0 Da fits deamidation of the asparagine, but the same shift would appear if a C-terminal amide were a free acid, so the note alone cannot tell them apart. -57.0 Da fits a glycine deletion, a process impurity fixed at manufacture. What the certificate cannot show is a diastereomer or a Leu/Ile swap co-eluting under the 97.8% main peak, because both have the target mass. Under the Ph. Eur. scheme two of these peaks would need to be identified, as they are above 0.5%. [1]
- Note each impurity peak with its percentage, retention time and mass shift.
- Mark which ones are degradation-type (oxidation, deamidation) and may change with storage age.
- Ask whether the main peak was checked for co-eluting isomers.
- Compare the same peaks across lots rather than only the main-peak figure.
Questions before you decide
What is the difference between a deletion and a truncated sequence?
A deletion is missing a residue from inside the chain. The EMA describes truncated sequences as the acetylated fragments made when unreacted chain ends are capped during SPPS.
Why does a +16 Da peak matter?
It is the mass of one added oxygen (15.995 Da in Unimod), which fits oxidation of methionine or another sensitive residue. It is a hypothesis to confirm, not an identification.
Can mass spectrometry find every impurity?
No. Stereoisomers and Leu/Ile swaps have exactly the target mass, so intact-mass MS cannot see them. The EMA notes diastereomers may need specific methods.
Check the underlying evidence
Sources & review dates
- European Medicines Agency: Guideline on the development and manufacture of synthetic peptides (EMA/CHMP/CVMP/QWP/367182/2025, effective 1 June 2026) ↗Accessed 30 Oct 2026
- Unimod accession 35: Oxidation ↗Accessed 30 Oct 2026
- Unimod accession 7: Deamidated ↗Accessed 30 Oct 2026
- Unimod accession 28: Gln to pyro-Glu ↗Accessed 30 Oct 2026
- Unimod accession 23: Dehydrated ↗Accessed 30 Oct 2026
- ExPASy FindMod: amino acid residue and modification masses ↗Accessed 30 Oct 2026
- Bachem: Handling and storage guidelines for peptides ↗Accessed 30 Oct 2026
Sources are documentary evidence. They do not establish firsthand testing of a listed supplier.